This listing identifies HCS01.1E-W0005-A-03-B-ET-EC-NN-NN-NN-FW for maintenance of installed IndraDrive Cs systems. Match the complete power, control, communication, feedback and safety configuration before selecting a spare. Each ordering-code field has a separate role.
| Complete Model | HCS01.1E-W0005-A-03-B-ET-EC-NN-NN-NN-FW |
|---|---|
| Power And Voltage Code | W0005 maximum-current code 5 A, not continuous current; 03: 3-phase AC 200–500 V |
| Control Design | B: BASIC |
| Main Communication | ET: Multi-Ethernet |
| Encoder Interface | EC: Multi-encoder interface |
| Optional Interface | NN: Not equipped |
| Safety Option | NN: Not equipped; system implementation must be validated |
| Other Design | NN: none in type-key field |
| Panel And Firmware | FW: type key specifies control panel; firmware is ordered separately; verify actual included items |
| Material Reference Status | R911326038; existing catalog reference, exact pairing and offered nameplate require confirmation |
The W0005 field is the manufacturer maximum-current code, 5 A, rather than an unconditional continuous-current rating. The 03 voltage class denotes 3-phase AC 200–500 V. Apply the actual supply connection, switching conditions, permitted motor combination and derating from the applicable hardware documentation.
This configuration combines BASIC control design with Multi-Ethernet. Match the firmware and configured network to the machine; a communication option does not mean every supported Ethernet protocol operates simultaneously.
NN in the optional-interface position means not equipped in that field. It does not remove the primary EC encoder interface or establish the status of other option positions.
NN in the safety-option position means that option is not equipped in the reviewed type key. Do not infer STO or Safe Motion from the HCS01 family name alone.
The FW ending denotes the control-panel arrangement in the type key while firmware is a separate order item. Confirm the actual panel, firmware version and included components of the offered unit.
Provide the full nameplate, material number, hardware index, firmware designation, motor and encoder requirements and the original machine circuit reference. Confirm the required panel, connectors, covers and accessories, together with the actual condition and available inspection evidence. Related configurations identify differences and do not establish interchangeable operation. Current availability and supply terms are confirmed in the quotation.
Technical reference: Rexroth R911322210, Edition05, type-code tables1-6 to1-8 and functional-equipment table4-3. Verify the complete hardware and firmware version; unconfirmed fields require additional documentation.
Contact Us at Any Time