The listed CSB02.5B-ET-EC-CN-L3-NN-NN-NW is a Rexroth IndraDrive single-axis control section. Match the complete option string when identifying a unit for maintenance or replacement; the family name alone does not specify the same interfaces.
| Complete Model | CSB02.5B-ET-EC-CN-L3-NN-NN-NW |
|---|---|
| Control Range | BASIC; single-axis |
| Interface Equipment | Extended scope (B) |
| Master Communication | ET: Multi-Ethernet |
| Interface 1 | EC: multi-encoder interface |
| Interface 2 | CN: CANopen interface |
| Safety Option (Interface 3) | L3: Safe Torque Off option |
| Interface 4 | NN: not equipped |
| Other Design | NN: none |
| Supply Designation | NW: without control panel and without firmware |
Interface 2 specifies CN CANopen. It is separate from ET in the master-communication position; replacing CN with EC or PB changes the listed interface arrangement.
The L3 safety position identifies the Safe Torque Off option. The actual safety function still depends on the complete drive and its validated application.
The .5 design is identified in the manufacturer type-code description for Hxx05 power sections. It must not be silently replaced by a .1 version on the basis of a similar option string.
The final NN before the firmware code is an Other Design field. It is not evidence that an operating panel is absent.
The NW suffix explicitly excludes the control panel and firmware. A comparison with an FW version must take this supply difference into account.
Confirm the complete nameplate, hardware identification, existing firmware and connected power section for the offered unit. Included panels, plugs and other accessories must be identified in the quotation. These comparison links describe configuration differences, not a guarantee of interchangeable operation.