Dengfeng (XinXing) Trading Co., Limited
Email: reginaqiu@dfmold168.com TEL: 86--13826708706
Home > Products > VFDs & AC Drives >
Danfoss VACON 0100-3L-0046-5 FLOW Pump and Fan AC Drive 380-500VAC 46A 22kW MR6
  • Danfoss VACON 0100-3L-0046-5 FLOW Pump and Fan AC Drive 380-500VAC 46A 22kW MR6

Danfoss VACON 0100-3L-0046-5 FLOW Pump and Fan AC Drive 380-500VAC 46A 22kW MR6

Place of Origin Denmark
Brand Name Vacon
Model Number VACON 0100-3L-0046-5 FLOW
Product Details
Mountingoptions:
Wall-mounted Or Panel-mounted
Controltype:
Vector Control And V/Hz Control
Voltagerange:
200 V To 690 V
Energysavingfeatures:
Automatic Energy Optimization
Coolingmethod:
Air Cooled
Ambienttemperaturerange:
-10°C To +50°C
Overloadcapacity:
150% For 60 Seconds
Powerrange:
0.37 KW To 250 KW
Safetyfeatures:
Safe Torque Off (STO) Function
Productname:
VACON 100 FLOW Drives
Userinterface:
LCD Display With Keypad
Type:
Variable Frequency Drive (VFD)
Communicationprotocols:
Modbus, CANopen, Profibus, DeviceNet
Application:
Pump And Fan Control
Ingressprotection:
IP21, IP54 Options
Payment & Shipping Terms
Minimum Order Quantity
1 unit
Price
USD 499 - 599 / Unit
Packaging Details
Anti-static Bag + Carton Box + Foam Protection
Payment Terms
T/T
Supply Ability
10 Units per Month
Product Description

Product Overview

The Danfoss VACON 0100-3L-0046-5 FLOW is a catalog-listed VACON 100 FLOW variable frequency drive base reference for three-phase 380-500 VAC pump, fan and process-flow applications.

The model provides 46 A continuous current under low-overload duty and is positioned for approximately 22 kW motor operation at 400 VAC. It uses the MR6 mechanical frame and is associated with wall-mounted IP21 or IP54 configurations.

The VACON 100 FLOW platform is intended for variable-torque systems using pressure, flow, level or temperature feedback. Complete fieldbus, option-board, enclosure and application-software details must be confirmed from the original nameplate or factory ordering information.

Main Features

  • Catalog-listed model: VACON 0100-3L-0046-5 FLOW
  • VACON 100 FLOW application drive
  • Three-phase 380-500 VAC voltage class
  • 46 A continuous low-overload current
  • 22 kW low-overload motor rating at 400 VAC
  • MR6 mechanical frame
  • Wall-mounted IP21 or IP54 configuration positioning
  • Dedicated pump and fan application positioning
  • PID and process-feedback control positioning
  • Multipump operation positioning
  • Suitable for water, wastewater and HVAC systems
  • Complete factory configuration requires verification

Technical Specifications

Model VACON 0100-3L-0046-5 FLOW
Family VACON 100
Subseries VACON 100 FLOW
Product Type Pump, Fan and Flow-Control AC Drive
Input Phase Three-phase
Voltage Class 380-500 VAC
Continuous Current IL 46 A
Low-Overload Motor Rating 22 kW at 400 VAC
High-Overload Rating Not applied to this FLOW product listing
Mechanical Frame MR6
Available Format Wall-mounted IP21 or IP54 configuration
Application Control PID, flow, pressure, level and multipump positioning
Primary Applications Pumps, fans, HVAC, water and wastewater
Configuration Note Verify enclosure, control unit, fieldbus and option codes
Supply Status Regional availability must be confirmed before quotation

Compatible System and Applications

The VACON 0100-3L-0046-5 FLOW can be used in booster-pump systems, circulation pumps, cooling-water systems, ventilation fans, air-handling units, cooling towers and water or wastewater process installations.

The drive should be selected according to motor current, required flow or pressure, process-feedback signal, operating-speed range and installation environment.

Multipump systems require verification of sequencing logic, auxiliary contactors, feedback transmitters, standby-pump operation and communication with the building or process-control system.

Maintenance and Replacement Notes

Do not remove the FLOW designation from the Model field. The corresponding INDUSTRIAL model may have a different application package and overload-selection basis.

Before replacing the drive, document the complete original reference, enclosure, control unit, fieldbus, option boards, PID configuration and application software.

Save the parameter set and record pressure or flow setpoints, transmitter scaling, motor data, acceleration and deceleration times, sleep and wake limits, pump-changeover logic, alarm functions and network settings.

Related Models

Related VACON 100 FLOW models include VACON 0100-3L-0038-5 FLOW, VACON 0100-3L-0061-5 FLOW and VACON 0100-3L-0072-5 FLOW.

Models with different voltage suffixes, enclosure configurations or application identities should remain separate product references.

Inquiry and Supply Notes

Please provide the complete drive and motor nameplates, pump or fan data, process-feedback type, enclosure requirement, fieldbus protocol, control diagram and parameter backup.

Exact application configuration, firmware, product condition, functional testing and delivery time must be confirmed before quotation.

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us