The Danfoss VACON 0100-3L-0072-5 FLOW is a catalog-listed VACON 100 FLOW drive base reference for three-phase 380-500 VAC variable-torque motor applications.
The model provides 72 A continuous low-overload current and is positioned for approximately 37 kW motor operation at 400 VAC. It uses the MR7 mechanical frame and is associated with wall-mounted IP21 or IP54 configurations.
The FLOW product identity is intended for pump, fan, HVAC, water and wastewater systems using process feedback and application-specific control functions. The complete configuration must be verified before quotation.
| Model | VACON 0100-3L-0072-5 FLOW |
| Family | VACON 100 |
| Subseries | VACON 100 FLOW |
| Product Type | Pump and Fan Process-Control Drive |
| Input Phase | Three-phase |
| Voltage Class | 380-500 VAC |
| Continuous Current IL | 72 A |
| Low-Overload Motor Rating | 37 kW at 400 VAC |
| High-Overload Rating | Not used for this FLOW listing |
| Mechanical Frame | MR7 |
| Available Format | Wall-mounted IP21 or IP54 configuration |
| Control Positioning | PID, pressure, flow, level and multipump functions |
| Primary Applications | Pumping, ventilation, HVAC, water and wastewater systems |
| Model Status | Catalog-grade base reference; full build requires verification |
| Supply Status | Regional availability varies; confirm before quotation |
The VACON 0100-3L-0072-5 FLOW can be applied to larger booster pumps, circulation pumps, cooling-water pumps, supply and exhaust fans, air-handling systems, cooling towers and water-treatment processes.
Selection should consider motor current, system pressure, flow range, pipe or duct characteristics, process-feedback signal, minimum operating speed and required control sequence.
The existing PLC, building-management system or supervisory-control network must be checked for compatible communication, start and stop commands, setpoint transfer and alarm handling.
VACON 0100-3L-0072-5 FLOW and VACON 0100-3L-0072-5 INDUSTRIAL must remain separate listings. The similar base code does not confirm identical application software or control behavior.
Before replacement, record the complete factory type code, enclosure, control-unit reference, fieldbus, option boards, firmware and application package.
Back up motor data, PID parameters, feedback scaling, sleep and wake settings, multipump sequencing, bypass logic, communication addresses and alarm configurations.
Related VACON 100 FLOW references include VACON 0100-3L-0061-5 FLOW, VACON 0100-3L-0087-5 FLOW and VACON 0100-3L-0105-5 FLOW.
Different voltage classes and configured enclosures must remain as separate quotation references.
Please provide the complete drive nameplate, motor data, pump or fan operating points, feedback transmitters, enclosure requirement, network protocol, control sequence and parameter backup.
Exact configuration, application software, firmware, functional testing and delivery time must be confirmed before quotation.