Dengfeng (XinXing) Trading Co., Limited
Email: reginaqiu@dfmold168.com TEL: 86--13826708706
Home > Products > Sensors & Transducers >
Dynisco TPT463E-7.5M-6/18 Melt Pressure and Temperature Transducer
  • Dynisco TPT463E-7.5M-6/18 Melt Pressure and Temperature Transducer

Dynisco TPT463E-7.5M-6/18 Melt Pressure and Temperature Transducer

Place of Origin USA
Brand Name Dynisco
Certification CE
Model Number TPT463E-7.5M-6/18
Product Details
Productname:
Dynisco Melt Pressure Transducer
Pressuretype:
Gauge Or Absolute
Type:
Pressure Transducer
Application:
Plastic Extrusion, Injection Molding
Electricalconnection:
Integral Cable Or Connector
Responsetime:
Less Than 1 Ms
Accuracy:
±0.25% Full Scale
Mountingtype:
Flush Or Flush With Diaphragm
Payment & Shipping Terms
Minimum Order Quantity
1 unit
Price
USD 1000 - 1500 / Unit
Packaging Details
Anti-static Bag + Carton Box + Foam Protection
Delivery Time
7-14 Days
Supply Ability
10 Units per Month
Product Description

Product Overview

The Dynisco TPT463E-7.5M-6/18 is a combined pressure-and-temperature model with a nominal 0 to 7,500 psi pressure range. It combines a 3.33 mV/V pressure bridge with a removable Type J thermocouple and is intended for melt-processing equipment requiring pressure and temperature information from one installation point.

This corrected model does not assume a Type K thermocouple. If the installed nameplate shows a special temperature-element suffix, that complete suffix must be supplied and verified separately.

Main Product Information

ModelTPT463E-7.5M-6/18
Pressure Range0 to 7,500 psi
Pressure Output3.33 mV/V nominal
Temperature InputType J thermocouple, standard configuration
Thread1/2-20 UNF
Mechanical FormRigid stem plus flexible capillary
Process TemperatureMaximum diaphragm temperature up to 400 degrees C

Application Positioning

The 7,500 psi range sits between common 5,000 and 10,000 psi configurations. It may provide suitable measurement resolution where normal operating pressure exceeds a 5,000 psi range but does not require a 10,000 psi full scale. Final selection must account for pressure peaks and required overload margin.

Typical Applications

  • Extrusion dies and melt lines
  • Polymer filtration equipment
  • Compounding and pelletizing systems
  • Plastic sheet and profile production
  • Process troubleshooting and replacement projects

Replacement Checklist

Confirm the full-scale range, temperature-element type, stem and flexible length, connector, process thread, pressure excitation and receiving-instrument scaling. Do not substitute a K-type temperature input unless the complete installed model and wiring prove that configuration.

Inquiry and Supply Notes

Send the nameplate and original wiring information for exact configuration review. Special suffixes and nonstandard temperature options require separate verification.

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us