Yaskawa CIMR-VU4A0023FAA V1000 VFD 480V 3-Phase 15HP 23A NEMA 1
  • Yaskawa CIMR-VU4A0023FAA V1000 VFD 480V 3-Phase 15HP 23A NEMA 1

Yaskawa CIMR-VU4A0023FAA V1000 VFD 480V 3-Phase 15HP 23A NEMA 1

Place of Origin Japan
Brand Name YASKAWA
Model Number CIMR-VU4A0023FAA
Product Details
Model:
CIMR-VU4A0023FAA
Input Power:
380-480 VAC, Three-Phase
Normal Duty Power:
15 HP
Heavy Duty Power:
10 HP
Normal Duty Output Current:
24.0 A
Heavy Duty Output Current:
19.2 A
Motor Control:
Induction And Permanent-Magnet Motor Control
Enclosure Rating:
IP20 / NEMA 1
Braking Transistor:
Built In
Payment & Shipping Terms
Minimum Order Quantity
1
Price
USD 980/Unit
Packaging Details
original packing
Delivery Time
3-5Days
Payment Terms
D/A, D/P, T/T, Western Union, ,
Supply Ability
20Units per Month
Product Description

Product Overview

The Yaskawa CIMR-VU4A0023FAA is a V1000 compact current-vector variable frequency drive developed for 380-480 VAC three-phase industrial motor systems. It provides a Normal Duty rating of 15 HP at 24.0 A and a Heavy Duty rating of 10 HP at 19.2 A. The two operating ratings allow the drive to serve either moderate-overload variable-torque equipment or more demanding constant-torque machinery.

Normal Duty operation is generally suited to centrifugal pumps, fans and similar loads with limited short-term overload demand. Heavy Duty operation provides 150% overload capacity for 60 seconds and is more appropriate for conveyors, mixers, processing equipment and machinery with higher starting torque. The final selection must be based on motor nameplate current, starting torque, acceleration time, operating cycle and ambient conditions rather than horsepower alone.

Main Features

  • 380-480 VAC three-phase industrial input
  • 15 HP and 24.0 A Normal Duty rating
  • 10 HP and 19.2 A Heavy Duty rating
  • Open Loop Current Vector control for improved low-speed torque
  • V/f control for conventional variable-speed applications
  • PM Open Loop Vector control for compatible permanent-magnet motors
  • Normal Duty overload capacity of 120% for 60 seconds
  • Heavy Duty overload capacity of 150% for 60 seconds
  • Built-in braking transistor for compatible external braking resistors
  • RS-422/485 serial communication supporting MEMOBUS/Modbus

Technical Specifications

Manufacturer Yaskawa
Complete Model CIMR-VU4A0023FAA
Series V1000
Product Type Compact Current Vector VFD
Input Voltage 380-480 VAC, Three-Phase
Normal Duty Rating 15 HP, 24.0 A
Heavy Duty Rating 10 HP, 19.2 A
Control Methods Open Loop Current Vector, V/f, PM Open Loop Vector
Overload Capacity ND 120% for 60 s; HD 150% for 60 s
Output Frequency 0-400 Hz Standard
Protective Design IP20 / NEMA 1
Braking Transistor Standard Built-in

Compatible System and Applications

The CIMR-VU4A0023FAA can operate appropriately rated three-phase induction motors and compatible permanent-magnet motors. Open Loop Current Vector control is suitable for applications requiring improved starting torque and speed regulation without conventional encoder feedback. V/f control is appropriate for straightforward variable-speed operation, while PM Open Loop Vector mode requires accurate motor electrical data and application-specific commissioning.

Typical applications include pumps, fans, conveyors, mixers, packaging lines, material-handling systems and process machinery. For high-inertia equipment or applications requiring frequent rapid deceleration, calculate the regenerative energy and braking duty. The built-in braking transistor requires an external resistor with the correct resistance, power rating and duty cycle.

Maintenance and Replacement Notes

When replacing an installed CIMR-VU4A0023FAA, confirm the complete model and suffix from the nameplate. Record the existing parameters, motor data, terminal functions, communication address, acceleration settings and braking configuration before removing the drive. Inspect the motor cable, motor insulation, grounding and mechanical load if the original unit experienced overcurrent, ground fault or overload events.

Some older V1000 documentation may show slightly different rounded output-current values for particular specification revisions. The installed nameplate and exact specification number should therefore be confirmed before quotation or replacement. Do not assume that another V1000 drive with similar horsepower is electrically interchangeable.

GA500 can be considered for migration of a V1000-controlled machine. Parameter conversion through DriveWizard Industrial can reduce setup time, but the output-current rating, terminal logic, safety wiring, communication option and braking components must still be reviewed.

Related Models for Comparison

  • CIMR-VU4A0005FAA — Normal Duty Power: 3 HP; Normal Duty Output Current: 5.4 A.
  • CIMR-VU4A0009FAA — Normal Duty Power: 5 HP; Normal Duty Output Current: 8.8 A.

Compare the complete model, electrical ratings, interface and mechanical options before selection. Related models are not confirmed direct replacements.

Inquiry and Supply Notes

Please provide the complete drive nameplate, motor power, motor rated current, required duty, application type and quantity. If the installation uses a braking resistor or communication option, include its model information for compatibility review.

Browse Yaskawa Variable Frequency Drives

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us