This page identifies TVM1.2-050-220/300-W1/220/380V for replacement enquiries on installed modular drive systems. Match TVM1.2 and the complete W1/220/380V auxiliary/ventilation configuration to the original unit and cabinet wiring.
| Complete Model | TVM1.2-050-220/300-W1/220/380V |
|---|---|
| Supply Family | Indramat TVM modular drive power supply |
| Hardware Generation | TVM1.2; preserve exact version |
| Type Current Class | 050: 50 A type current; not a universal continuous output guarantee |
| Nominal Main Input | 220 V AC, +/-15% in reviewed family table; verify actual wiring |
| Nominal DC Link | 300 V DC, +/-15% in reviewed family table |
| Ventilation Configuration | W1; verify original fan arrangement and fan supply separately |
| Auxiliary Voltage Code | 220/380V retained as cataloged; compare auxiliary transformer setting |
| Controller Supply Evidence | TVM1 table: +24VL output 24-30 V, 4 A; not evidence of regulated 24 V compatibility |
| Material Reference Status | R911221600; catalog reference, exact offered pairing pending |
TVM1.2 and the full W1/220/380V ending identify this supply configuration. Keep 220/380V separate from the 220/300 main-input/DC-link field. The trailing auxiliary values do not establish that the main power input can be connected directly to either voltage.
The reviewed TVM1 family table lists 50 A type current and 150 A short-duration peak current for 300 ms. Continuous duty must be checked with the connected drive package and cooling conditions; 050 must not be promoted to an unconditional continuous-current specification.
The W1 ventilation field and fan voltage need comparison with the original hardware. The family data distinguish supply, auxiliary and fan circuits. Confirm the fan assembly, transformer taps and terminal arrangement before offering a spare with another suffix.
TVM1 is shown with separate ventilated and non-ventilated data. Its controller supply capacity differs from TVM2.1/2.2. Do not copy the later TVM2.4 data or assume a regulated 24 V supply from the auxiliary-voltage designation.
The catalog designation includes a final V character. It remains unchanged here; verify the exact original label spelling and auxiliary connection before quotation.
Provide the original power-supply and transformer labels, material number, hardware index, terminal photographs, connected drive modules and cabinet schematic. Identify fan and auxiliary connections, existing braking components and required connectors or covers. Actual condition, inspection information and included accessories are confirmed for the offered unit. Similar type current or external appearance does not establish interchangeability.
Technical reference: MAC Servo Drives with TDM/KDS, 9.552.268.4-01, January1994, chapter12 figures105/106. Family table values require checking against the actual version and installation.