The TVM2.2-050-220/300-W1/115/220 is listed as a Rexroth Indramat TVM power supply spare part for maintenance of installed legacy AC drive systems. Public spare-parts catalogs associate this configuration with R911229493. Identification, actual unit condition and completeness are checked for each quotation. Please provide the complete original nameplate and the machine's spare-parts requirement so the requested supply can be matched accurately.
| Complete model designation | TVM2.2-050-220/300-W1/115/220 |
| Catalog model used for this listing | TVM2.2-050-220/300-W1/115/220 |
| Product Family | Indramat TVM |
| Product Type | Modular AC drive power supply |
| Design Series | TVM2.2 |
| Type Current Code | 050 type-current class; not a confirmed continuous output rating |
| Main Input | Three-phase 220 VAC, 50/60 Hz; verify actual revision |
| Nominal DC Bus | 300 VDC nominal bus; verify actual unit rating |
| Cooling Method | W1: internal blower configuration; verify fan assembly |
| Control Supply | 115/220 VAC configuration; verify connection setting |
| Configuration Code | W1/115/220; match full type plate and hardware index |
| Material Number | R911229493 (catalog reference; actual nameplate verification required) |
Multiple independent spare-parts catalogs identify R911229493 as TVM2.2-050-220/300-W1/115/220. This page preserves the TVM2.2 design version and the W1 cooling configuration. Match the material number and full original nameplate before ordering; the version and cooling code are essential parts of the identification.
The 220/300 section identifies the main input and nominal DC-bus voltage classes. The final W1/115/220 section must be checked separately as the cooling and control-supply configuration. It should not be interpreted as a broad main-input range. Historical TVM documentation distinguishes supplies without an internal blower from blower-equipped versions. The actual fan condition, control-voltage connection setting and hardware revision must match the original installation.
The TVM family provides DC-bus power and control voltages for a modular AC drive installation. During braking, returned energy must be handled within the original power-system design. The presence and sizing of capacitance, bleeder and other auxiliary components affect the installation requirements. This page does not describe the TVM as a guaranteed line-regenerative replacement. Identify the components already installed with the machine when requesting the spare module.
The 050 field is retained as a type-current designation. It is not automatically stated as the continuous output current under all operating conditions. Confirm continuous and peak ratings, environmental limits and permitted loading from the documentation for the exact hardware version. A material number supports identification, but a quotation must still identify the actual unit offered. Neither a larger rating code nor a similar housing establishes suitability for a particular machine.
Send a clear photograph of the original supply's complete type plate, including the model, R911 number, serial number and hardware index. Add front and connection-area photographs if the label is incomplete or if mounting parts and connectors are important. State the connected drive-module types, original control-supply arrangement and machine spare-parts reference. Drawings or service records can help resolve an abbreviated description before an exact sourcing request is confirmed.
Check the incoming AC supply, DC-bus connections, control-voltage wiring and cooling assembly against the proposed unit. Record which covers, plugs, mounting brackets and fan parts are required. Auxiliary transformers, capacitance and bleeder modules are supplied only when specifically identified in the quotation. The buyer's responsible technician should review the complete electrical and mechanical configuration and the commissioning requirements. This enquiry listing does not guarantee compatibility with another model or revision.
This is a discontinued / legacy genuine spare-part enquiry listing. A quotation will describe the proposed original unit and its stated condition. Tell us whether unused surplus, previously used equipment or another condition is acceptable. Inspection and test evidence, where available, will be described for that particular unit. Please distinguish a module-only requirement from a complete assembly with connectors, covers, cooling parts or other accessories included.
For stored or previously operated equipment, available history and inspection records help assess the proposed supply. Exterior appearance alone does not establish electrical condition or readiness for recommissioning. If a particular test, document or pre-dispatch check is required, include it in the enquiry so its availability can be assessed. A fixed testing scope or warranty period is not assigned to every sourced unit. Final condition and commercial terms relate to the actual offered equipment.
Request TVM2.2-050-220/300-W1/115/220, material reference R911229493, with the required quantity, acceptable condition and delivery destination. Attach the original label photographs and identify any essential hardware-index or configuration requirement. If an alternative is proposed, obtain its full identification and review it against the machine documentation before deciding whether it meets the maintenance requirement.
The displayed USD 344.79 per piece is a historical same-model eBay budget reference, calculated at 65% of an observed eBay asking price for TVM2.2-050-220/300-W1/115/220 (USD 530.44). The reference listing has ended, so the figure is a historical pricing benchmark. Availability, actual condition, included items, freight and applicable charges require a final quotation. The reference seller's inventory, delivery and warranty statements are not assigned to this listing.
Minimum order quantity is 1 piece. The supply target is 10 pieces per month, subject to actual availability. When an in-stock unit is confirmed, dispatch is normally within one week. Non-stock sourcing and dispatch dates are agreed separately. Payment terms and protective export packaging are confirmed with the quotation. Request current availability before scheduling a maintenance shutdown and include the required arrival date in your enquiry.
Can a W0 and a W1 supply be treated as the same spare?
The cooling configuration is part of the replacement review. Match the original full code, material number, control-supply arrangement and hardware index before selecting a unit.
Does the page confirm immediate stock or manufacturer authorization?
Stock, condition and included items are confirmed for the actual offered unit. This listing does not imply an official agency relationship, a fixed inventory commitment or an unverified warranty.
Contact Us at Any Time