This page identifies TVD1.3-15-03/S007 for maintenance enquiries involving installed modular drive systems. The complete design, power code and suffix must match the original unit or be reviewed against the machine documentation before a replacement is accepted.
| Complete Model | TVD1.3-15-03/S007 |
|---|---|
| Product Type | Legacy TVD modular-drive power supply |
| Design Version | TVD1.3; match the original design and hardware index |
| Power Code | 15: 15 kW continuous DC-bus code in manual section8.1; confirm special version |
| DC Bus Code | 03: 320 V code in section8.1; confirm complete version |
| Main Supply | TVD1.3 base: 3-phase AC 380–480 V (±10%), 50–60 Hz; exact special version must be checked |
| Energy Handling | TVD1.3 reference uses a bleeder for braking energy; not a line-regenerative supply |
| Special Design | S007; function and parameter differences not independently established |
| Version Evidence | TVD1.3 base data and full type-code structure reviewed; offered unit not verified |
| Material Reference Status | Exact material number not confirmed; original nameplate required |
The TVD1.3-15 base technical table distinguishes 15 kW continuous DC-bus power from 45 kW peak power for 0.3 seconds. The bus rating is 320 V with a ±5% tolerance in that table. Apply the rated conditions and verify any special design before transferring these figures to the complete offered unit.
The base application documentation pairs the 15 supply class with NAM1.3-15. Its alternative individual-component arrangement identifies KD23, CZ1.2-01-7 and GLD17. These are system-planning references, not a promise that accessories are included or that every suffix uses identical wiring.
Section3.10 gives a maximum additional DC-bus capacitance of 120 mF for this TVD1.3 power class. Confirm the original machine design, installed capacitance and braking duty when matching a supply.
The S007 suffix remains part of TVD1.3-15-03/S007. Its exact function and hardware differences have not been confirmed. A matching base designation does not establish replacement equivalence with a different suffix.
The TVD1.3 reference handles regenerated braking energy with a bleeder arrangement, with auxiliary TBM equipment where specified. Do not describe the supply as feeding braking energy back to the mains. Match the original system and complete design before choosing associated components.
Provide clear nameplate photographs showing the complete type, material number and hardware index. Include the connected drive modules, original mains equipment, choke and braking components, required connectors and machine circuit reference. Confirm the offered condition, completeness and available inspection records. Related-model links identify configuration differences and do not establish interchangeable operation. Current availability, accessories and delivery terms are confirmed in the quotation.
Technical reference: TVD1.3 application manual, ANW1, sections2.2, 2.4, 3 and 8.1. Apply the documentation for the complete design; special suffixes and other revisions need separate confirmation.
Contact Us at Any Time