Danfoss 131B0456 FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive

Place of Origin Denmark
Brand Name Danfoss
Model Number FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX
Product Details
Productname:
Danfoss VLT AutomationDrive FC 302
Coolingmethod:
Built-in Fan Cooling
Controltype:
Vector Control With Or Without Encoder
Protectionclass:
IP20 (standard), Optional IP54
Mountingoptions:
Wall-mounted Or Panel-mounted
Overloadcapacity:
150% For 60 Seconds
Voltagerange:
200 V To 690 V
Userinterface:
Graphical Display With Keypad
Operatingtemperaturerange:
-10°C To 50°C
Powerrange:
0.18 KW To 250 KW
Type:
Frequency Converter / Variable Frequency Drive
Payment & Shipping Terms
Minimum Order Quantity
1 unit
Price
USD 599 - 899 / Unit
Packaging Details
Anti-static Bag + Carton Box + Foam Protection
Payment Terms
T/T
Supply Ability
10 Units per Month
Product Description

Product Overview

The Danfoss 131B0456 is an exact VLT AutomationDrive FC 302 frequency-converter configuration identified by the complete type code FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX.

This drive is rated for 4 kW / 5.5 HP and operates from a three-phase 380-500 VAC mains supply. It uses an E20 IP20 chassis enclosure intended primarily for installation inside an electrical cabinet.

The complete configuration includes an H1 RFI Class A1/B (C1) filter, graphical local control panel and A0 PROFIBUS communication option. It does not include a brake chopper, coated PCB or additional mains option.

Relevant procurement searches include 131B0456, FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX, FC-302P4K0T5, Danfoss FC302 4kW PROFIBUS, FC302 5.5HP and VLT AutomationDrive FC 302 IP20.

Main Features

  • Danfoss commercial reference: 131B0456
  • Complete type code: FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX
  • Short search model: FC-302P4K0T5
  • VLT AutomationDrive FC 302 product family
  • 4 kW / 5.5 HP power rating
  • Three-phase 380-500 VAC mains supply
  • E20 IP20 chassis enclosure
  • H1 RFI Class A1/B (C1) filter
  • No brake chopper
  • Graphical local control panel included
  • Not coated PCB
  • No additional mains option
  • A0 PROFIBUS communication option
  • No additional B, C or D option

Technical Specifications

Part Number 131B0456
Complete Model FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX
Short Search Model FC-302P4K0T5
Product Series VLT AutomationDrive FC 302
Product Type Industrial Variable Frequency Drive
Power Rating 4 kW / 5.5 HP
Input Phase Three-phase
Mains Voltage 380-500 VAC
Enclosure Code E20
Protection Class IP20 chassis
RFI / EMC Filter H1, RFI Class A1/B (C1)
Brake Chopper Not included
Local Control Panel Graphical LCP included
PCB Coating Not coated
Mains Option No additional mains option
Adaptation A Standard cable entries
Adaptation B No additional adaptation
Software Release Standard software release
A Option A0, PROFIBUS communication option
B Option No B option
C Option No C option
D Option No D option
Installation Electrical cabinet installation normally required
Supply Status Confirm condition, hardware revision and regional availability before quotation

Compatible System and Applications

The 131B0456 can be evaluated for conveyors, packaging machines, mixers, dosing equipment, winding systems and production machinery connected to an existing PROFIBUS automation network.

Communication compatibility must be checked against the installed PLC, PROFIBUS master, node address, baud rate, telegram profile, process-data mapping and original project configuration.

Final drive selection must also consider motor current, overload duty, required starting torque, acceleration cycle and installation environment.

Maintenance and Replacement Notes

For exact replacement, match both 131B0456 and FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX.

The A0 PROFIBUS option is a major compatibility requirement. A standard FC-302P4K0T5 without the same communication option may not connect correctly to the existing control system.

This configuration does not include a brake chopper. Verify braking requirements separately before replacing a drive used with rapid stopping or regenerative loads.

Back up the complete parameter file and document the PROFIBUS address, process-data configuration, motor data, I/O assignments, ramp settings and safety parameters.

Related Models

Related exact configurations include 131B0040 for an H1 graphical-LCP version without the PROFIBUS option, and 131B0070 for an H2 brake-chopper version.

Products with different A-option codes must remain separate exact-SKU pages because the installed communication interfaces differ.

Inquiry and Supply Notes

Please provide the original drive nameplate, PLC type, PROFIBUS network information, motor data, required quantity, braking requirements and parameter backup.

Confirm whether the A0 PROFIBUS option and graphical LCP are mandatory.

Exact condition, hardware revision, included accessories, testing scope, firmware, warranty, packaging and delivery time must be confirmed before quotation.

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us