Dengfeng (XinXing) Trading Co., Limited
Email: reginaqiu@dfmold168.com TEL: +86--13826708706
Home > Products > Sensors & Transducers >
Gefran F034502 KE1-6-M-B35D-1-4-D-S 2130X000X00 Melt Transmitter
  • Gefran F034502  KE1-6-M-B35D-1-4-D-S 2130X000X00 Melt Transmitter

Gefran F034502 KE1-6-M-B35D-1-4-D-S 2130X000X00 Melt Transmitter

Place of Origin USA
Brand Name Gefran
Model Number KE1-6-M-B35D-1-4-D-S 2130X000X00 / F034502
Product Details
Brand:
Gefran
Model:
KE1-6-M-B35D-1-4-D-S 2130X000X00 / F034502
Product Type:
NaK-Filled Melt Pressure Transmitter
Series / Control Platform:
KE Series / Sodium-Potassium (NaK)
Pressure Range:
0–350 Bar (nominal 5000 Psi Class) / <±0.5% FS
Output / Accuracy Class:
2-Wire 4–20 MA / 10–30 VDC / 6-Pin Connector
Process Connection / Installation:
1/2-20 UNF / 153 Mm Rigid Stem With 457 Mm Flexible Capillary
Ordering Requirement:
Verify The Complete Model, F034502 Code, 2130X000X00 Suffix, Pressure Range, S Diaphragm Option, Connector And Nameplate Before Ordering
Payment & Shipping Terms
Minimum Order Quantity
1 unit
Price
USD 1034/Unit
Packaging Details
original packing
Delivery Time
7-14 Days
Payment Terms
T/T
Supply Ability
2 Units per Month
Product Description

Product Overview

Gefran KE1-6-M-B35D-1-4-D-S 2130X000X00, identified by Gefran code F034502, is a KE-series melt pressure transmitter for pressure measurement in heated polymer, extrusion and high-temperature process equipment. It uses sodium-potassium alloy, or NaK, as the hydraulic pressure-transfer medium and provides a two-wire 4–20 mA signal for connection to a compatible PLC, process controller or indicator.

Why This 350 Bar Configuration Matters

The B35D pressure code identifies the 0–350 bar configuration, corresponding to the nominal 5000 psi class. This range is commonly selected when normal process pressure requires more headroom than a 100 or 200 bar transmitter but does not justify the reduced resolution associated with a 500 or 700 bar range. The receiving channel must still be scaled from 4 mA at zero pressure to 20 mA at 350 bar.

Verified Technical Specifications

Complete ModelKE1-6-M-B35D-1-4-D-S 2130X000X00
Gefran CodeF034502
Pressure Range0–350 bar
Accuracy ClassM, less than ±0.5% FS
Output and SupplyTwo-wire 4–20 mA; 10–30 VDC
Electrical Connection6-pin connector; IP65 when correctly mated
Process Connection1/2-20 UNF
Mechanical Configuration153 mm rigid stem with 457 mm flexible capillary
Contact Diaphragm OptionS: 15-5 PH stainless steel with GTP+ coating
Maximum Diaphragm Temperature400°C for the specified S diaphragm option

Installation and Loop Configuration

Depressurize and cool the process before removal. Inspect the mounting hole for hardened polymer, damaged threads or an incorrect seat, and do not apply installation force to the sensing diaphragm. Route the flexible section away from sharp bends, moving machinery and concentrated radiant heat. Confirm loop polarity, supply voltage, cable shielding and the exact 6-pin wiring diagram before energizing the transmitter.

Related Models and Selection Differences

KE1-6-M-B05C-1-4-D-S 2130X000X00 (F046485) increases the range to 500 bar. KE1-6-M-B01C-1-4-D-S 2130X000X00 (F040926) is the 100 bar configuration. KE1-6-M-P05M-1-4-D-S 2130X000X00 (F049682) uses a psi-based 5000 psi order code, while KE1-6-M-P10M-1-4-D-S 2130X000X00 (F036156) is rated for 10000 psi. Even where nominal ranges appear similar, the complete nameplate code and controller scaling must match. Related models are provided for family reference only and are not automatically interchangeable.

Inquiry and Supply Notes

Specify F034502 together with the complete model and suffix. Confirm the pressure unit, diaphragm option, process thread, rigid and flexible lengths, connector, existing cable and required product condition before quotation. Availability, production status and delivery time require separate confirmation.

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us