Gefran KE1-6-M-B05C-1-4-D-S 2130X000X00 Melt Transmitter

Place of Origin USA
Brand Name Gefran
Model Number KE1-6-M-B05C-1-4-D-S 2130X000X00
Product Details
Brand:
Gefran
Model:
KE1-6-M-B05C-1-4-D-S 2130X000X00
Product Type:
NaK-Filled Melt Pressure Transmitter
Series / Control Platform:
KE Series / Sodium-Potassium (NaK)
Pressure Range:
0–500 Bar (nominal 7500 Psi Class) / <±0.5% FS
Output / Accuracy Class:
2-Wire 4–20 MA / 10–30 VDC / 6-Pin Connector
Process Connection / Installation:
1/2-20 UNF / 153 Mm Rigid Stem With 457 Mm Flexible Capillary
Ordering Requirement:
Match F046485, The Complete 2130X000X00 Code, 500 Bar Scaling, S Diaphragm, Connector And Mechanical Dimensions To The Nameplate
Payment & Shipping Terms
Minimum Order Quantity
1 unit
Price
USD 1034/Unit
Packaging Details
original packing
Delivery Time
7-14 Days
Payment Terms
T/T
Supply Ability
2 Units per Month
Product Description

Product Identity and Function

Gefran KE1-6-M-B05C-1-4-D-S 2130X000X00 is a 500 bar NaK-filled melt pressure transmitter with Gefran material code F046485. It converts pressure acting on the high-temperature process diaphragm into a two-wire 4–20 mA signal. Typical uses include extrusion lines, polymer processing equipment and machinery where the electronic housing must be separated from the hottest measurement point by a rigid stem and flexible capillary.

Control-System Scaling

The B05C code specifies a 0–500 bar measuring span, also associated with the nominal 7500 psi class. A controller configured for the 350 bar B35D version will display an incorrect pressure when connected to this transmitter, even though the electrical signal format is the same. During commissioning, configure 4 mA as 0 bar and 20 mA as 500 bar, then verify the engineering unit used by alarms, trends and shutdown logic.

Confirmed Configuration

ModelKE1-6-M-B05C-1-4-D-S 2130X000X00
Gefran Material CodeF046485
Measurement Range0–500 bar
AccuracyM class, less than ±0.5% FS
Transmission FluidNaK sodium-potassium alloy
Analog SignalTwo-wire 4–20 mA
Supply Voltage10–30 VDC
Connector6-pin; IP65 with the correct mating connector
Mounting Thread1/2-20 UNF
Stem Arrangement153 mm rigid section plus 457 mm flexible section
DiaphragmS option, 15-5 PH stainless steel with GTP+ coating
Maximum Diaphragm Temperature400°C for this S configuration

Replacement Checks

Do not select this unit only because another KE1 transmitter has the same connector or 4–20 mA output. Confirm the existing process thread, pressure span, stem lengths, diaphragm option and full 2130X000X00 code. Before installation, clean the sensor bore with an appropriate maintenance tool and make sure no frozen process material can contact or side-load the diaphragm. Verify loop polarity and grounding before applying power.

Range Alternatives

KE1-6-M-B35D-1-4-D-S 2130X000X00 (F034502) is the 350 bar version and can provide finer usable resolution where the process remains below that limit. KE1-6-M-B01C-1-4-D-S 2130X000X00 (F040926) covers 100 bar. KE1-6-M-P10M-1-4-D-S 2130X000X00 (F036156) is a 10000 psi configuration. Safety-certified, external-autozero and alternative diaphragm suffixes represent separate configurations. Related models are provided for family reference only and are not automatically interchangeable.

Ordering Information

Request the product using both F046485 and the complete model. Supply status, calibration documentation, cable inclusion and product condition must be confirmed for the individual quotation rather than inferred from the series designation.

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us