Place of Origin USA
Brand Name Gefran
Model Number ME2-6-M-B35D-1-4-D 2130X000X00 / F007783
Product Details
Brand:
Gefran
Model:
ME2-6-M-B35D-1-4-D 2130X000X00 / F007783
Product Type:
Melt Pressure And Temperature Transmitter
Series / Control Platform:
ME2 Series / Mercury-Filled Pressure Transmission
Pressure Range:
0–350 Bar / <±0.5% FS
Electrical Output / Interface:
2-Wire 4–20 MA / Isolated Type J Thermocouple / 6-Pin Connector
Process Connection / Stem:
1/2-20 UNF / 153 Mm Rigid Stem With 457 Mm Flexible Capillary
Ordering Requirement:
Verify F007783, Complete 2130X000X00 Code, Pressure Span, Type J Input Compatibility, Connector Pinout And Installation Dimensions
Payment & Shipping Terms
Minimum Order Quantity
1 unit
Price
USD 1262/Unit
Packaging Details
original packing
Delivery Time
7-14 Days
Payment Terms
T/T
Supply Ability
2 Units per Month
Product Description

Product Overview

Gefran ME2-6-M-B35D-1-4-D 2130X000X00, Gefran code F007783, is a combined melt pressure and temperature transmitter for high-temperature extrusion and polymer-processing equipment. The pressure section uses a mercury-filled hydraulic transmission system and produces a two-wire 4–20 mA output. The ME2 configuration also incorporates an isolated Type J thermocouple, allowing pressure and process temperature to be monitored from the same installation point.

Two Independent Measurement Channels

The pressure loop and thermocouple must be treated as separate signals. Connect the 4–20 mA circuit to a correctly powered analog current input and connect the Type J conductors to a compatible thermocouple input with the correct polarity and cold-junction compensation. A standard analog voltage input cannot directly interpret the thermocouple signal. Verify the exact six-pin wiring diagram before commissioning.

Verified Configuration

Complete ModelME2-6-M-B35D-1-4-D 2130X000X00
Gefran CodeF007783
Pressure Range0–350 bar
Pressure AccuracyM class, less than ±0.5% FS
Pressure OutputTwo-wire 4–20 mA
Supply Voltage10–30 VDC
Temperature ElementIsolated Type J thermocouple
Electrical Interface6-pin connector; IP65 when correctly mated
Process Connection1/2-20 UNF
Stem Configuration153 mm rigid stem plus 457 mm flexible capillary
Maximum Diaphragm Temperature400°C

Installation and Signal Verification

Cool and depressurize the machine before removal. Confirm the mounting bore and thread, protect the diaphragm from mechanical contact and route the capillary without tight bends. At startup, verify that the pressure input is scaled from 0 to 350 bar and that the temperature channel is configured specifically for Type J. Check thermocouple polarity if temperature moves in the wrong direction during warm-up.

Related Models and Channel Differences

ME2-6-M-B05C-1-4-D 2130X000X00 (F007769) retains the same basic signal concept but increases pressure range to 500 bar. ME2-6-M-B07C-1-5-D 2130X000X00 (F007779) is a 700 bar version with a different stem-length code. ME1-6-M-B35D-1-4-D 2130X000X00 (F007725) is a pressure-only ME1 transmitter and does not provide the ME2 Type J temperature channel. Related models are provided for family reference only and are not automatically interchangeable.

Ordering and Replacement Notes

Confirm F007783, the full suffix, Type J requirement, pressure range, connector pinout, existing cable, rigid and flexible lengths and process connection. Do not replace an ME2 with an ME1 unless the temperature channel is intentionally removed and the machine design has been reviewed.

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us