Gefran ME2-6-M-B35D-1-4-D 2130X000X00, Gefran code F007783, is a combined melt pressure and temperature transmitter for high-temperature extrusion and polymer-processing equipment. The pressure section uses a mercury-filled hydraulic transmission system and produces a two-wire 4–20 mA output. The ME2 configuration also incorporates an isolated Type J thermocouple, allowing pressure and process temperature to be monitored from the same installation point.
The pressure loop and thermocouple must be treated as separate signals. Connect the 4–20 mA circuit to a correctly powered analog current input and connect the Type J conductors to a compatible thermocouple input with the correct polarity and cold-junction compensation. A standard analog voltage input cannot directly interpret the thermocouple signal. Verify the exact six-pin wiring diagram before commissioning.
| Complete Model | ME2-6-M-B35D-1-4-D 2130X000X00 |
| Gefran Code | F007783 |
| Pressure Range | 0–350 bar |
| Pressure Accuracy | M class, less than ±0.5% FS |
| Pressure Output | Two-wire 4–20 mA |
| Supply Voltage | 10–30 VDC |
| Temperature Element | Isolated Type J thermocouple |
| Electrical Interface | 6-pin connector; IP65 when correctly mated |
| Process Connection | 1/2-20 UNF |
| Stem Configuration | 153 mm rigid stem plus 457 mm flexible capillary |
| Maximum Diaphragm Temperature | 400°C |
Cool and depressurize the machine before removal. Confirm the mounting bore and thread, protect the diaphragm from mechanical contact and route the capillary without tight bends. At startup, verify that the pressure input is scaled from 0 to 350 bar and that the temperature channel is configured specifically for Type J. Check thermocouple polarity if temperature moves in the wrong direction during warm-up.
ME2-6-M-B05C-1-4-D 2130X000X00 (F007769) retains the same basic signal concept but increases pressure range to 500 bar. ME2-6-M-B07C-1-5-D 2130X000X00 (F007779) is a 700 bar version with a different stem-length code. ME1-6-M-B35D-1-4-D 2130X000X00 (F007725) is a pressure-only ME1 transmitter and does not provide the ME2 Type J temperature channel. Related models are provided for family reference only and are not automatically interchangeable.
Confirm F007783, the full suffix, Type J requirement, pressure range, connector pinout, existing cable, rigid and flexible lengths and process connection. Do not replace an ME2 with an ME1 unless the temperature channel is intentionally removed and the machine design has been reviewed.
Contact Us at Any Time