Dengfeng (XinXing) Trading Co., Limited
Email: reginaqiu@dfmold168.com TEL: +86--13826708706
Home > Products > Sensors & Transducers >
Gefran ME2-6-M-B01C-1-5-D 2130X000X00 F007762 Melt Transmitter Type J
  • Gefran  ME2-6-M-B01C-1-5-D 2130X000X00  F007762 Melt Transmitter Type J

Gefran ME2-6-M-B01C-1-5-D 2130X000X00 F007762 Melt Transmitter Type J

Place of Origin USA
Brand Name Gefran
Model Number ME2-6-M-B01C-1-5-D 2130X000X00 / F007762
Product Details
Brand:
Gefran
Model:
ME2-6-M-B01C-1-5-D 2130X000X00 / F007762
Product Type:
Low-Range Melt Pressure And Temperature Transmitter
Series / Control Platform:
ME2 Series / Mercury-Filled Pressure Transmission
Pressure Range:
0–100 Bar / <±0.5% FS
Electrical Output / Interface:
2-Wire 4–20 MA / Type J Thermocouple / 6-Pin Connector
Process Connection / Stem:
1/2-20 UNF / 318 Mm Rigid Stem With 457 Mm Flexible Capillary
Ordering Requirement:
Confirm F007762, 100 Bar Scaling, Code-5 Rigid Stem, Type J Thermocouple, Connector Wiring And Complete Suffix
Payment & Shipping Terms
Minimum Order Quantity
1 unit
Price
USD 1262/Unit
Packaging Details
original packing
Delivery Time
7-14 Days
Payment Terms
T/T
Supply Ability
2 Units per Month
Product Description

Product Identity

Gefran ME2-6-M-B01C-1-5-D 2130X000X00, order code F007762, is a 100 bar melt pressure transmitter with an integrated Type J thermocouple. Unlike the shorter code-4 ME2 configuration, this model uses rigid-stem code 5, corresponding to a 318 mm or 12.5 inch rigid section. The longer rigid stem is a defined mechanical configuration and must be matched to the installed machine rather than treated as a minor dimensional variation.

Low-Range Measurement Considerations

The B01C code specifies a 0–100 bar pressure span, associated with the nominal 1500 psi class. This range can provide better usable resolution on lower-pressure extrusion processes, but the selected span must accommodate startup pressure, cold-material conditions and process transients. It is not suitable merely because the normal running pressure is below 100 bar; validated peak pressure must also be considered.

Confirmed Specifications

ModelME2-6-M-B01C-1-5-D 2130X000X00
Gefran Material CodeF007762
Pressure Range0–100 bar
Accuracy ClassM, less than ±0.5% FS
Pressure SignalTwo-wire 4–20 mA
Supply Requirement10–30 VDC
Temperature SignalType J thermocouple
Connector6-pin; verify the mating connector and pinout
Process Thread1/2-20 UNF
Rigid Stem318 mm / 12.5 inches
Flexible Section457 mm / 18 inches
Maximum Diaphragm Temperature400°C

Why Stem Code 5 Must Be Verified

The extended rigid section changes the sensor’s mechanical reach and the position of the flexible transition. Before replacement, compare the installed insertion geometry, heater arrangement, available clearance and routing path. A shorter code-4 stem may physically fit the same thread but place the flexible section and electronics in a different thermal environment.

Commissioning Notes

Scale the current input from 0 to 100 bar. Connect the thermocouple to a Type J-compatible channel with correct polarity and cold-junction compensation. Keep the thermocouple circuit separate from the powered 4–20 mA loop. Confirm the six-pin diagram because connector appearance alone does not establish identical wiring.

Related Models

ME2-6-M-B01C-1-4-D 2130X000X00 (F007760) retains the 100 bar range but uses a 153 mm rigid stem. ME2-6-M-B35D-1-5-D 2130X000X00 (F007788) keeps the longer code-5 stem but increases the pressure range to 350 bar. ME2-6-M-B07C-1-5-D 2130X000X00 (F007779) is the corresponding 700 bar long-stem configuration. Related models are provided for family reference only and are not automatically interchangeable.

Ordering Requirement

Provide F007762 together with the full model and a nameplate photograph. Verify the 100 bar span, code-5 rigid length, flexible length, Type J channel, process thread, connector and product condition before ordering.

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us