The HVE04.2-W075N is listed for replacement enquiries involving installed Rexroth DIAX04 systems. Identify the complete supply designation, generation and special code before matching an offered spare. This page separates the HVE supply role from motor-axis and PLC specifications.
| Complete Model | HVE04.2-W075N |
|---|---|
| Product Family | DIAX04 HVE power supply unit |
| Supply Function | Unregulated DC-bus supply; confirm the original machine configuration |
| Design Generation | HVE04.2; do not substitute another generation without verification |
| Power And Cooling Code | W075N; preserve every designation character |
| Special Design Code | No additional special code in the listed designation |
| Main Supply | Base second-generation data: 3-phase AC 380–480 V (±10%), 50–60 Hz (±2 Hz); confirm exact version |
| DC Bus | Base second-generation HVE: 530–670 V (±10%), unregulated; input-dependent |
| Version Evidence | Base configuration included in AW07 manual; special suffix still requires confirmation |
| Material Reference Status | R911190002; existing reference, exact manufacturer pairing and offered nameplate require confirmation |
The HVE04.2 base housing is listed with a width of 250 mm, and the base electrical data sheet lists a mass of 28 kg. Confirm the dimensional drawing for the complete suffix and hardware revision rather than transferring mounting details from another size.
For the HVE04.2-W075N base version at 3 × AC 400 V, figure4-4 distinguishes 35 kW continuous DC-bus power without a DC-bus choke from 75 kW with the assigned GLD20. These are configuration-dependent figures, not a universal promise from the numerical model code. Exact suffix versions require confirmation.
HVE uses an unregulated DC bus and dissipates regenerated energy through the bleeder arrangement. It is not the same energy-return design as HVR. Evaluate the original supply, DC-bus choke and braking duty together.
Provide photographs of the full original nameplate, material number, hardware index and terminal arrangement, plus the connected drive types and machine circuit reference. Confirm which connectors, covers and auxiliary components are required. Supply mode, generation, DC-bus loading, braking duty and cabinet clearances must be checked together. Related model links identify differences and do not establish interchangeable operation. Condition, completeness, availability and delivery are confirmed for the offered unit in the quotation.
Technical reference: Rexroth DIAX04 HVE/HVR application manual, AW07, sections4.2/4.3 and chapter7. Base second-generation data must be checked against the complete version and actual unit.
Contact Us at Any Time