The Schneider ATV610D30N4 is a medium-power process variable speed drive from the Easy Altivar 610 series. It is rated for 30 kW Normal Duty and 22 kW Heavy Duty operation on a three-phase 380–460 VAC power supply.
This standard N4 version includes a display terminal, embedded Modbus serial communication, an integrated Category C3 EMC filter and an integrated DC choke.
The ATV610D30N4 is designed for pumps, fans, compressors, conveyors, water-treatment systems, cooling equipment and plant-utility installations.
| Model | ATV610D30N4 |
| Series | Easy Altivar 610 |
| Product Type | Process Variable Speed Drive |
| Variant | Standard N4 Version |
| Display Terminal | Included |
| Frame Size | Frame 4 |
| Protection Rating | IP20 |
| Supply Voltage | Three-phase 380–460 VAC, -15% / +10% |
| Supply Frequency | 50/60 Hz ±5% |
| Normal Duty Power | 30 kW / 40 HP |
| Normal Duty Output Current | 61.5 A |
| Normal Duty Maximum Transient Current | 67.7 A |
| Normal Duty Input Current at 380 V | 62.5 A |
| Normal Duty Input Current at 460 V | 55.8 A |
| Normal Duty Apparent Power | 44.5 kVA |
| Heavy Duty Power | 22 kW / 30 HP |
| Heavy Duty Output Current | 46.3 A |
| Heavy Duty Maximum Transient Current | 69.5 A |
| Heavy Duty Input Current at 380 V | 49.7 A |
| Heavy Duty Input Current at 460 V | 42.5 A |
| Heavy Duty Apparent Power | 33.9 kVA |
| Maximum Inrush Current | 91 A |
| Normal Duty Overload | 110% for 60 seconds or 120% for 20 seconds |
| Heavy Duty Overload | 150% for 60 seconds |
| Compatible Motor Types | Three-phase asynchronous and compatible permanent-magnet synchronous motors |
| Communication | Embedded Modbus serial |
| EMC Filter | Integrated optimized filter, IEC/EN 61800-3 Category C3 |
| DC Choke | Integrated |
| Maximum Output Frequency | Up to 500 Hz |
| Cooling | Forced convection |
| Installation | Industrial electrical cabinet mounting |
| Dimensions | Approximately 226 * 613.1 * 270.8 mm |
| Reference Weight | Approximately 25.5 kg |
The ATV610D30N4 is suitable for centrifugal pumps, industrial fans, compressors, conveyors, cooling plants, water and wastewater equipment and general process systems.
The 30 kW Normal Duty rating is intended for loads with moderate overload requirements. Applications requiring greater starting torque or 150% overload should use the 22 kW Heavy Duty rating for selection.
Verify the full ATV610D30N4 reference and do not select the drive based only on the 30 kW power value.
Record the original motor data, duty mode, I/O assignments, process setpoints, Modbus parameters and fault history before replacement.
Inspect the cooling fans, DC-bus capacitors, power terminals, display terminal, grounding and cabinet heat dissipation.
ATV610D30N4Z is the related version supplied without the display terminal.
Adjacent standard N4 models include ATV610D22N4 and ATV610D37N4.
Please provide the existing drive model, motor nameplate, application, motor rated current, Normal Duty or Heavy Duty requirement and cabinet information.
Firmware, communication options, display requirements, product condition, functional testing, packaging, availability and delivery time must be confirmed before quotation.