The Schneider ATV610D75N4 is a higher-power process variable speed drive from the Easy Altivar 610 series. It is rated for 75 kW Normal Duty operation and 55 kW Heavy Duty operation on a three-phase 380–460 VAC supply.
This standard N4 model includes a display terminal, embedded Modbus serial communication, an integrated optimized Category C3 EMC filter and an integrated DC choke.
The ATV610D75N4 is intended for large pumps, industrial fans, compressors, water-treatment systems, cooling plants, conveyors and building or plant-energy equipment.
| Model | ATV610D75N4 |
| Series | Easy Altivar 610 |
| Product Type | Process Variable Speed Drive |
| Variant | Standard N4 Version |
| Display Terminal | Included |
| Frame Size | Frame 5 |
| Protection Rating | IP20 |
| Supply Voltage | Three-phase 380–460 VAC, -15% / +10% |
| Supply Frequency | 50/60 Hz ±5% |
| Normal Duty Power | 75 kW / 100 HP |
| Normal Duty Output Current | 145 A |
| Normal Duty Maximum Transient Current | 159.5 A |
| Normal Duty Input Current at 380 V | 147.9 A |
| Normal Duty Input Current at 460 V | 130.2 A |
| Normal Duty Apparent Power | 103.7 kVA |
| Heavy Duty Power | 55 kW / 75 HP |
| Heavy Duty Output Current | 106 A |
| Heavy Duty Maximum Transient Current | 159 A |
| Heavy Duty Input Current at 380 V | 115.8 A |
| Heavy Duty Input Current at 460 V | 101.7 A |
| Heavy Duty Apparent Power | 81 kVA |
| Maximum Inrush Current | 186 A |
| Normal Duty Overload | 110% for 60 seconds or 120% for 20 seconds |
| Heavy Duty Overload | 150% for 60 seconds |
| Compatible Motor Types | Three-phase asynchronous and compatible permanent-magnet synchronous motors |
| Communication | Embedded Modbus serial |
| EMC Filter | Integrated optimized filter, IEC/EN 61800-3 Category C3 |
| DC Choke | Integrated |
| Maximum Output Frequency | Up to 500 Hz |
| Cooling | Forced convection |
| Installation | Industrial electrical cabinet mounting |
| Dimensions | Approximately 290 * 762 * 322.5 mm |
| Reference Weight | Approximately 53 kg |
The ATV610D75N4 is suitable for large centrifugal pumps, industrial fans, compressors, water and wastewater systems, cooling plants, large conveyors and building-energy applications.
The 75 kW power value applies to Normal Duty. Applications requiring 150% short-term overload should be selected using the 55 kW Heavy Duty rating and 106 A output-current limit.
Installation engineering must include cable sizing, upstream protection, cabinet airflow, heat dissipation, grounding and safe lifting or handling arrangements.
Verify the complete ATV610D75N4 reference, display-terminal requirement, motor current and operating duty.
Record all motor parameters, process settings, Modbus addresses, I/O assignments, acceleration and deceleration settings and fault history before replacement.
Inspect the cooling fans, DC-bus capacitors, power terminals, bus connections, display terminal, grounding and cabinet ventilation. A powered motor test is recommended where practical.
ATV610D75N4Z is the related version supplied without the display terminal.
Adjacent standard N4 models include ATV610D55N4 and ATV610D90N4.
Please provide the complete drive nameplate, motor nameplate, motor current, supply voltage, operating duty, application load, enclosure dimensions and cooling conditions.
Display-terminal requirements, communication options, product condition, functional testing, packaging method, availability and delivery time must be confirmed before quotation.