The Dynisco PT4624-3.5M-6/18-SIL2 is a lower-range two-wire melt-pressure transmitter with a nominal pressure range of 0 to 3,500 psi and a 4-20 mA output. It is intended for processes where a lower full-scale range can provide more useful pressure resolution than 5,000 or 10,000 psi versions.
The device uses a rigid sensing stem and flexible capillary to separate the electronics housing from the high-temperature process area. The SIL2 suffix identifies a safety-oriented configuration, subject to validation within the complete control and safety system.
| Complete Model | PT4624-3.5M-6/18-SIL2 |
| Pressure Range | 0 to 3,500 psi |
| Signal Output | Two-wire 4-20 mA |
| Process Thread | 1/2-20 UNF |
| Stem Arrangement | Rigid stem with flexible capillary |
| Safety Configuration | SIL2 device configuration |
| Maximum Diaphragm Temperature | Up to 400 degrees C |
A lower pressure range can improve control resolution when the process normally operates below 3,500 psi. The selection must still provide adequate margin for startup peaks, blocked-screen conditions and process disturbances. The model should not replace a higher-range transmitter without confirming actual maximum pressure.
Confirm maximum operating pressure, transient peaks, 4-20 mA scaling, loop supply, load resistance, mechanical dimensions, connector pinout and process thread. Review the applicable SIL documentation and proof-test requirements for safety-related use.
Provide the complete nameplate, process-pressure range, connected PLC or controller and safety-document requirements before ordering.
PT4624-3.5M-6/18-SIL2: 0-3500 psi; Two-wire 4-20 mA pressure output; 1/2-20 UNF. Match the complete reference to the installed instrument or sensor before ordering.
| Model Reference | PT4624-3.5M-6/18-SIL2 |
| Sensor Function | Melt pressure transmitter |
| Signal Output | Two-wire 4-20 mA pressure output |
| Calibrated Pressure Range | 0-3500 psi |
| Process Thread | 1/2-20 UNF |
| Rigid Stem Length | 6 in |
| Flexible Capillary Length | 18 in |
| Excitation Or Loop Supply | 24 VDC nominal; verify loop supply and load for the fitted revision |
Compare the differences below against the machine requirements. These references are not confirmed direct substitutes.
For quotation, provide the full nameplate, installed wiring and calibration or configuration requirements. Confirm product condition and availability before ordering.
Browse the functional category: Dynisco Melt Pressure Transmitters. Technical reference: Dynisco manufacturer documentation.