The Schneider BMXAMI0410 is a four-channel isolated high-level analog input module for the Modicon X80 automation platform. It is designed to acquire standard industrial current and voltage signals from transmitters, measurement instruments and process-control equipment.
The module supports commonly used signal ranges including 0–20 mA, 4–20 mA and positive or negative 10 V voltage signals. Its isolated input architecture helps reduce unwanted interaction between field measurement circuits and the PLC system.
The BMXAMI0410 is suitable for Modicon M340 and compatible X80-based control systems. Exact rack, CPU, firmware, terminal block and project compatibility must be checked before replacement.
| Model | BMXAMI0410 |
| Series | Modicon X80 |
| Product Type | Isolated Analog Input Module |
| Number of Inputs | 4 |
| Input Level | High Level |
| Isolation | Isolated input architecture |
| Current Input Range | 0–20 mA and 4–20 mA |
| Voltage Input Range | Positive or negative 10 V |
| Platform | Compatible Modicon X80 architecture |
| Engineering Software | EcoStruxure Control Expert |
| Legacy Software | Older projects may use Unity Pro |
| Channel Configuration | Configured individually in the PLC project |
| Scaling | Application- and signal-range-dependent |
| Terminal Block | Confirm required removable terminal block and wiring accessories |
| Firmware | Verify installed revision and project compatibility |
| Supply Status | Regional availability varies; confirm before quotation |
The BMXAMI0410 is suitable for acquiring analog signals from pressure transmitters, flowmeters, level transmitters, temperature transmitters, current converters and industrial measurement instruments.
Typical applications include water treatment, process skids, pumping systems, production machinery, HVAC equipment and manufacturing lines.
The configured signal range must match the connected transmitter. Applying a voltage signal to a current-configured channel, or incorrect loop wiring, may result in invalid readings or equipment damage.
Verify the complete BMXAMI0410 reference before replacement. BMXAMI0800 and BMXAMI0810 provide eight inputs and use different isolation arrangements.
Before removing the original module, record its rack and slot position, channel ranges, scaling parameters, diagnostic settings, terminal wiring and firmware revision.
After replacement, validate each channel using a known current or voltage source and compare the PLC engineering value with the field measurement.
Related analog input modules include BMXAMI0800 with eight non-isolated inputs and BMXAMI0810 with eight isolated inputs.
BMXART0414 and BMXART0814 are temperature-input modules and should be handled in a separate temperature-module batch.
Please provide the complete module reference, CPU and rack models, slot position, input-signal ranges, terminal-block requirement, firmware and Control Expert project information.
Product condition, terminal accessories, firmware compatibility, channel testing, regional availability and delivery time must be confirmed before quotation.