The Danfoss 060G3557 is an MBS 3050 heavy-duty hydraulic pressure transmitter with the complete specification key MBS 3050-3435-A1GB04-2.
This model measures sealed-gauge pressure from 0 to 250 bar and provides a 0–10 V voltage output. It is equipped with a G 1/4 DIN 3852-E process connection, angular Pg 9 electrical connector and integrated pulse snubber.
The MBS 3050 construction is intended for hydraulic applications affected by cavitation, liquid hammer and rapid pressure peaks. The integrated pulse snubber helps reduce the influence of these severe pressure conditions on the sensing element.
| Brand | Danfoss |
|---|---|
| Product Type | Pressure Transmitter |
| Series | MBS 3050 |
| Commercial Reference | 060G3557 |
| Specification Key | MBS 3050-3435-A1GB04-2 |
| Pressure Range | 0–250 bar / 0–3625 psi |
| Pressure Reference | Sealed Gauge |
| Output Signal | 0–10 V |
| Supply Voltage | 15–32 VDC |
| Pressure Connection | G 1/4 Male |
| Pressure Connection Standard | DIN 3852-E / ISO 1179-2 Form E |
| Electrical Connection | Angular Connector, Pg 9 |
| Electrical Connection Standard | EN 175301-803-A |
| Pulse Snubber | Integrated |
| Enclosure Rating | IP65 |
| Typical Accuracy | ±0.5% FS |
| Maximum Accuracy | ±1% FS |
| Maximum Overload Pressure | 600 bar |
| Autofrettage Pressure | 1600 bar |
| Medium Temperature Range | -40°C to +85°C |
| Ambient Temperature Range | -40°C to +85°C |
| Response Time | Maximum 4 ms |
| Pin 1 | Positive Supply |
|---|---|
| Pin 2 | Common / Ground |
| Pin 3 | Positive Output |
Always verify the pin assignment against the product label and equipment wiring diagram before energizing the transmitter.
The 060G3557 uses a 0–10 V output and requires a 15–32 VDC supply. It must not be connected directly to a controller configured only for a 4–20 mA input.
The G 1/4 DIN 3852-E process connection uses a different sealing arrangement from G 1/4 EN 837. Check the process-port geometry, seal and installation requirements before replacing another G 1/4 transmitter.
Do not mechanically clean or enlarge the internal pressure passage. The integrated pulse snubber is part of the transmitter’s protection system and may be damaged by incorrect cleaning.
Please identify this transmitter using both 060G3557 and MBS 3050-3435-A1GB04-2. Confirm the 0–250 bar pressure range, 0–10 V output, 15–32 VDC supply, G 1/4 process connection and angular connector before ordering.
For replacement inquiries, providing a clear photograph of the existing product label and electrical connector will reduce the risk of selecting an incompatible signal or connection.