Dengfeng (XinXing) Trading Co., Limited
Email: reginaqiu@dfmold168.com TEL: 86--13826708706
Home > Products > Servo Drives & Motion Control >
B&R 8BVI0220HWD0.000-1 ACOPOSmulti 22A Dual-Axis Inverter
  • B&R 8BVI0220HWD0.000-1 ACOPOSmulti 22A Dual-Axis Inverter

B&R 8BVI0220HWD0.000-1 ACOPOSmulti 22A Dual-Axis Inverter

Place of Origin Germany
Brand Name B&R
Model Number 8BVI0220HWD0.000-1
Product Details
Module Type:
Dual-Axis Inverter Module
Product Family:
ACOPOSmulti
Number Of Motor Outputs:
2
Continuous Motor Power:
16 KW Per Motor Connection
Continuous Output Current:
22 Aeff Per Motor Connection
Peak Output Current:
5 Aeff Per Motor Connection
Possible Switching Frequencies:
5 / 10 KHz
Mounting Type:
Wall Mounting
Protection Class:
IP20
Plug-in Module Slots:
2
Payment & Shipping Terms
Minimum Order Quantity
1
Price
USD4620-4800/Unit
Packaging Details
original packing
Delivery Time
2-3Weeks
Payment Terms
D/A, D/P, T/T, Western Union, ,
Supply Ability
2 Units per Month
Product Description

Product Overview

The B&R 8BVI0220HWD0.000-1 is an ACOPOSmulti dual-axis inverter module containing two independent power inverters in one wall-mounted unit. Each motor connection supports 16 kW continuous motor power, 22 Aeff continuous current and 55 Aeff peak current.

The dual-axis construction can reduce the cabinet space required for machines with paired or coordinated servo axes. It is particularly different from the similarly named 8BVI0220HWS0.000-1, which is a single-axis module.

Main Product Information

ParameterValue
Material Number8BVI0220HWD0.000-1
Module ConfigurationTwo-axis inverter module
Motor Outputs2
Continuous Power16 kW per motor connection
Continuous Current22 Aeff per motor connection
Peak Current55 Aeff per motor connection
Nominal DC Bus Voltage750 VDC
Switching Frequencies5 / 10 kHz
Holding-Brake Outputs2 * 24 VDC, 2.1 A each
Dimensions106.5 * 317 * 263 mm
Approximate Weight5.7 kg
Protection ClassIP20

Dual-Axis Configuration

The module has two motor connections, two temperature-sensor connections and two holding-brake outputs. Although both axes are housed in one module, motor sizing and drive parameters must be checked independently for each connected axis.

The module supports two ACOPOSmulti plug-in-module slots. The installed encoder, communication or safety modules must be identified before replacement because the base inverter material number alone does not describe the complete machine configuration.

Replacement Checklist

  • Confirm the HWD0 dual-axis designation.
  • Check the full 8BVI0220HWD0.000-1 material number.
  • Record both motor models and their rated-current requirements.
  • Identify the plug-in modules installed in Slot 1 and Slot 2.
  • Verify both encoder cables, brake circuits and temperature-sensor wiring.
  • Back up both axis parameter sets before removing the original module.
  • Confirm the mandatory terminal block set and connector arrangement.

Contact Us at Any Time

13826708706
No. 8 Xinxing Wenxing Road, Guangdong Province, China
Send your inquiry directly to us